JET A-1
APPEARANCE (1)
Clear & Bright
VISUAL
TOTAL ACID NO.
MGKOH/G
0.015
ASTM
D 3242
AROMATICS
VOL PCT
25.0
ASTM
D 1319
SULPHUR CONTENT
WT PCT
0.30
IP
336
MERCAPTAN SULPHUR
PPM
30
ASTM
D 3227
HYDROPROCESSED COMPONENTS IN BATCH
VOL PCT
0
100
REPORT
INITIAL BOILING POINT
DEG C
ASTM
D 86
10 % RECOVERED AT
DEG C
205.0
ASTM
D 86
20 % RECOVERED AT
DEG C
ASTM
D 86
50 % RECOVERED AT
DEG C
ASTM
D 86
90 % RECOVERED AT
DEG C
ASTM
D 861
FINAL BOILING POINT
DEG C
300.0
ASTM
D 86
DISTILLATION RESIDUE
VOL PCT
1.5
ASTM
D 86
DISTILLATION LOSS
VOL PCT
1.5
ASTM
D 86
FLASH POINT
DEG C
38.0
IP
170
DENSITY AT 15 DEG C
KG/M3
775.0
840.0
ASTM
D 4052
FREEZING POINT
DEG C
-47.0
ASTM
D 2386
KINEMATIC VISCOSITY AT -20 DEG C
CST
8,000
ASTM
D 445
NET SPECIFIC ENERGY
MJ/KG
42.80;
ASTM
D 3338
SMOKE POINT
MM
19.0
IP
57
NAPHTHALENES
VOL PCT
3.00
ASTM
D 1840
COPPER STRIP CORROSION, 2 HRS @ 100 DEG C
NO.
1
ASTM
D 130
FILTER PRESSURE DIFFERENTIAL
MM HG
25.0
ASTM
D 3241
TUBE DEPOSIT RATING (2)
RATING
3
ASTM
D 3241
GUM EXISTENT CONTENT
MG/100 ML
7
IP
540
MSEP RATING
85
ASTM
D 3948
ANTIOXYDANT CONTENT (RDE/A/610) (6)
MG/L
17.0
24.0
REPORT
METAL DEACTIVATOR
PPM
5.7
REPORT
STADIS 450 (RDE/A/621) SUPPLIED (4)
KG
REPORT
PARTICULATE CONTAMINATION CONTENT (3)
MG/L
1.00
ASTM
D 5452
COLOUR SAYBOLT (3)
ASTM
D 156
SEVERELY H/P CONTENT IN BATCH
VOL PCT
PARTICULATE COUNTS
IP
564
>4 MICRONS
CNTS/ML
IP
564
>6 MICRONS
CNTS/ML
IP
564
>14 MICRONS
CNTS/ML
IP
564
>21 MICRONS
CNTS/ML
IP
564
>25 MICRONS
CNTS/ML
IP
564
>30 MICRONS)
CNTS/ML
IP
564
Product meets the requirements of AFORJOS Check List 24 except for electrical conductivity.
-
(1) Clear, bright and visually free from solid matter and undissolved water at normal and ambient temperature.
-
(2) No 'Peacock' or 'Abnormal' color deposits.
-
(3) At point of manufacture.
-
(4) Stadis 450 is supplied separately on board of ship (0.8 mg/l)
-
(5) Revision 15 of this specification meets the requirements of issue 24 of the Aviation Fuel Requirements for jointly Operated Systems, dated: October 2008.
-
(6) 18 mg/l antioxidant added to hydroprocessed components only.
Yukarıdaki bilgiler genel kabul gören standart değerleri göstermektedir.